DNA ANTIBODIES - serum
Specimen: 5 mL blood in
plain tube.
Method: Immunoassay.
Reference Interval: Method dependent - consult pathologist. Commonly <5 IU/mL.
Application: For confirmation of diagnosis or monitoring of SLE. Sensitivity
approximately 70%.
Interpretation: High levels are strongly suggestive of active SLE, particularly
with renal involvement. Lesser elevations may be found occasionally in other autoimmune
disorders.
Reference: Borg EJ et al. Arthritis Rheum 1990; 33: 634-643.